This specification covers requirements for the methods of application and finishing of gypsum board. Construction details for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories. Gypsum board assembly shall conform to acoustical tests of the specification where sound control is required. Moreover, gypsum assembly shall conform to framing size, fasteners spacing, ventilation, substrate, surface preparation, cutting, and installation application as indicated in the specification. Materials categorized under this specification include: gypsum boards, gypsum wallboards, gypsum backing board and coreboard, water-resistant gypsum backing board, exterior gypsum soffit board, and gypsum ceiling board. Finishing materials include: compounds, joint tape, fasteners, nails, screws, and staples. A fire test of assemblies shall be conducted to determine a fire resistance rating required for gypsum board assembly. Gypsum board shall be cut by scoring and breaking or by sawing, working from the face side. Masonry or concrete walls shall be dry, free of dust, oil, or form release agents, protrusions or voids, or foreign matter that inhibit bond for adhesively applied gypsum board. All materials shall be kept dry. Where gypsum board is stored outside, it shall be off the ground, properly supported on a level platform and fully protected from the weather or direct sunlight exposure.
The assembly is sketched schematically (inset) and is 5/8” type ‘x’ gypsum board, 3/8” wood shear panel, 2x6 studs at 16” o.c., R-19 fiberglass batt insulation, resilient channel, 5/8” type ‘x’ gypsum board. X 5/8 The 12 ft. Gypsum Board has a type-x fire-shield core with added non-combustible fibers that that helps delay heat transfer to structural members. It is designed to provide a high degree of fire resistance.
This standard is referenced in the 2012 International Building Code®.
Subdivision 09 21 16 Gypsum Board Assemblies. As the reader may suspect, these are basic guidelines and the appropriately inquisitive. Type and difficulty of. The Gypsum Construction Handbook. The Gypsum Construction Handbook or any of the chapters may be downloaded and viewed in PDF format. Adobe Acrobat Reader is required to view PDF files. B) Ante-room shall be constructed from one-hour fire-rated 5/8-in type “X” gypsum board one side of metal stud wall, mudded and taped in accordance with ASTM C840. C) Contractor shall add appropriate infection control measures (e.g., plastic sheeting between metal studs and gypsum board). Refer to 01 01 10-IC for more information.
• Change your LoL account password to an extremely secure password using your new Keepass database. • This one is important, save your keepass database. League of legends garena phising.